Cold start capability
Provides temporary battery power in the absence of other sources.
Counter
Provides actual consumption in kilowatt hours for energy-conscious users
Green fashion
Operational mode, for which a patent has been applied for, which bypasses unused electrical components under good power conditions to achieve a high degree of operational efficiency without sacrificing any protection.
High online efficiency
It reduces electricity costs and generates less heat
Intuitive LCD interface
It provides clear and precise information in numerous languages with the ability to configure the UPS locally via easy-to-use navigation codes.
Battery replacement date prediction
It independently indicates the month and year in which battery replacement is recommended to aid long-term maintenance planning.
Pre-installed network management card
Possibility of remote control and management of the UPS via network without additional software
Single group of switched outlets
Single outlet group that can be controlled separately from the UPS for selective rebooting of locked devices, sequential powering on and off, and shedding of non-critical loads.
SmartSlot
Possibility to customize the UPS functions via the management cards.
Temperature compensated battery charging
Extends battery life by adjusting charging voltage based on actual battery temperature.
Availability
Battery disconnection signal
Indicates the inability of a battery to provide emergency power.
Automatic restart of loads after UPS shutdown
Automatically starts connected devices when mains power is restored.
Automatic test
Regular battery self-diagnosis allows you to know in good time when a battery needs to be replaced.
Intelligent battery management
Optimizes battery performance, life and reliability through intelligent precision charging.
Temperature compensated battery charging
Extends battery life by adjusting charging voltage based on actual battery temperature.
Automatic voltage regulation (AVR) of boost and trim type
Provides superior application availability by correcting low and high voltage conditions without using battery power.
Power stabilization
Protects connected loads against surges, voltage spikes, lightning and other electrical disturbances.
Ease of management
Manageable via network
Allows remote management of the UPS across the network.
Serial connectivity
Allows management of the UPS through a serial port.
Audible alarms
Active control indicating if the unit is running on battery power, if the battery charge is low or if overload conditions exist.
Battery disconnection signal
Indicates the inability of a battery to provide emergency power.
LED status indicators
Quickly understand drive and power status with visual indicators.
USB connectivity
Possibility of managing the UPS through the USB port.
Safety
Certified by security agencies
It ensures the testing of products and their safety certification for operation with connected loads and within the customer's environment.
Marketing features
Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery management
The patented eco-operation mode increases efficiency by 97%. Smart-UPS are the first networked UPS with Energy Star certification. Intelligent battery management introduced by APC optimizes battery performance and life through precision temperature-compensated charging. The dynamic battery replacement date indicator and automatic tests ensure battery reliability and alert operators in advance when they need to be replaced. Convenient, easy-to-connect, hot-swappable battery modules allow you to replace batteries without interrupting power. Smart-UPS, designed and manufactured by APC for more than 23 years, are the most reliable network uninterruptible power supplies available on the market, with more than 25 million units sold.
Save time with the simplicity and convenience of remote access
Manageable on network via serial connection, USB or optional Ethernet. Includes Powerchute® Business Edition Software for monitoring and control, safe operating system shutdown, and cutting-edge power management capabilities.
Smarter productivity by customizing to your specific needs
The intuitive LCD interface provides clear information and allows you to configure the UPS locally with easy-to-use navigation keys. Over 15 different programmable settings, including switched outlet group control, let you choose settings, thresholds and notifications for any application.
The peace of mind that comes from full equipment compatibility and the reliability of a leader
The perfectly sine wave output is recommended by server manufacturers using active power factor correction (PFC) power supplies. The verification and approval of safety bodies implies the possibility of distributing Smart-UPS with the guarantee of total compliance with the most rigorous standards in the sector.
Avoid costly power problems by keeping your IT equipment and data safe and available
Grid-level power conditioning protects against dangerous surges and harmful noise. Solid-state automatic voltage regulation boosts under-input voltage by up to 30% and cuts over-voltage by up to 12% without using batteries. Reliable backup batteries that ensure power in the event of a blackout and safe shutdown of systems
Easy maintenance
Resettable circuit breakers
Enables rapid recovery from overload events
Hot-swappable batteries
Continuous, uninterrupted power to protect your device while you replace the batteries.
Preventive fault reporting
It enables timely fault analysis which ensures timely replacement of components.
User replaceable batteries
Increases availability by allowing an expert user to perform upgrades and replace batteries while reducing mean time to repair (MTTR)
Battery failure warning
It provides a timely analysis of battery failures, encouraging timely preventive maintenance interventions
Adaptability
Adjustable tension adjustment points
Optimize battery life by widening the input voltage or limiting the regulation of the output voltage.
Adjustable voltage sensitivity
Allows adaptation of the UPS for optimal performance in specific power environments or generator applications.
Provides temporary battery power in the absence of other sources.
Counter
Provides actual consumption in kilowatt hours for energy-conscious users
Green fashion
Operational mode, for which a patent has been applied for, which bypasses unused electrical components under good power conditions to achieve a high degree of operational efficiency without sacrificing any protection.
High online efficiency
It reduces electricity costs and generates less heat
Intuitive LCD interface
It provides clear and precise information in numerous languages with the ability to configure the UPS locally via easy-to-use navigation codes.
Battery replacement date prediction
It independently indicates the month and year in which battery replacement is recommended to aid long-term maintenance planning.
Pre-installed network management card
Possibility of remote control and management of the UPS via network without additional software
Single group of switched outlets
Single outlet group that can be controlled separately from the UPS for selective rebooting of locked devices, sequential powering on and off, and shedding of non-critical loads.
SmartSlot
Possibility to customize the UPS functions via the management cards.
Temperature compensated battery charging
Extends battery life by adjusting charging voltage based on actual battery temperature.
Availability
Battery disconnection signal
Indicates the inability of a battery to provide emergency power.
Automatic restart of loads after UPS shutdown
Automatically starts connected devices when mains power is restored.
Automatic test
Regular battery self-diagnosis allows you to know in good time when a battery needs to be replaced.
Intelligent battery management
Optimizes battery performance, life and reliability through intelligent precision charging.
Temperature compensated battery charging
Extends battery life by adjusting charging voltage based on actual battery temperature.
Automatic voltage regulation (AVR) of boost and trim type
Provides superior application availability by correcting low and high voltage conditions without using battery power.
Power stabilization
Protects connected loads against surges, voltage spikes, lightning and other electrical disturbances.
Ease of management
Manageable via network
Allows remote management of the UPS across the network.
Serial connectivity
Allows management of the UPS through a serial port.
Audible alarms
Active control indicating if the unit is running on battery power, if the battery charge is low or if overload conditions exist.
Battery disconnection signal
Indicates the inability of a battery to provide emergency power.
LED status indicators
Quickly understand drive and power status with visual indicators.
USB connectivity
Possibility of managing the UPS through the USB port.
Safety
Certified by security agencies
It ensures the testing of products and their safety certification for operation with connected loads and within the customer's environment.
Marketing features
Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery management
The patented eco-operation mode increases efficiency by 97%. Smart-UPS are the first networked UPS with Energy Star certification. Intelligent battery management introduced by APC optimizes battery performance and life through precision temperature-compensated charging. The dynamic battery replacement date indicator and automatic tests ensure battery reliability and alert operators in advance when they need to be replaced. Convenient, easy-to-connect, hot-swappable battery modules allow you to replace batteries without interrupting power. Smart-UPS, designed and manufactured by APC for more than 23 years, are the most reliable network uninterruptible power supplies available on the market, with more than 25 million units sold.
Save time with the simplicity and convenience of remote access
Manageable on network via serial connection, USB or optional Ethernet. Includes Powerchute® Business Edition Software for monitoring and control, safe operating system shutdown, and cutting-edge power management capabilities.
Smarter productivity by customizing to your specific needs
The intuitive LCD interface provides clear information and allows you to configure the UPS locally with easy-to-use navigation keys. Over 15 different programmable settings, including switched outlet group control, let you choose settings, thresholds and notifications for any application.
The peace of mind that comes from full equipment compatibility and the reliability of a leader
The perfectly sine wave output is recommended by server manufacturers using active power factor correction (PFC) power supplies. The verification and approval of safety bodies implies the possibility of distributing Smart-UPS with the guarantee of total compliance with the most rigorous standards in the sector.
Avoid costly power problems by keeping your IT equipment and data safe and available
Grid-level power conditioning protects against dangerous surges and harmful noise. Solid-state automatic voltage regulation boosts under-input voltage by up to 30% and cuts over-voltage by up to 12% without using batteries. Reliable backup batteries that ensure power in the event of a blackout and safe shutdown of systems
Easy maintenance
Resettable circuit breakers
Enables rapid recovery from overload events
Hot-swappable batteries
Continuous, uninterrupted power to protect your device while you replace the batteries.
Preventive fault reporting
It enables timely fault analysis which ensures timely replacement of components.
User replaceable batteries
Increases availability by allowing an expert user to perform upgrades and replace batteries while reducing mean time to repair (MTTR)
Battery failure warning
It provides a timely analysis of battery failures, encouraging timely preventive maintenance interventions
Adaptability
Adjustable tension adjustment points
Optimize battery life by widening the input voltage or limiting the regulation of the output voltage.
Adjustable voltage sensitivity
Allows adaptation of the UPS for optimal performance in specific power environments or generator applications.
Display type | LCD |
Rack mounting kit | Yes |
Packaging depth | 980mm |
Humidity | 0 - 95% |
Sustainability certificates | Green Premium, RoHS |
Cables included | Input power cable, USB cable |
Surge protection | Yes |
Web-based management | Yes |
AC output type | C20 coupler |
Quantity per pallet | 8 pcs |
Audible alarm mode | Battery replacement |
Weight | 42.2kg |
Quick installation guide | Yes |
Input operating voltage (max) | 302V |
UPS topology | Online interactive |
Automatic restart | Yes |
Emergency Power Off (EPO) | OR |
Battery capacity | 509 Ah |
Hot swap battery | Yes |
output frequency | 50/60 Hz |
automatic battery test | Yes |
Cold start | Yes |
Certification | CE, EAC, EN/IEC 62040-1, EN/IEC 62040-2, GS Mark, IRAM, RCM, VDE, WEEE |
Output voltage | 230V |
Output voltage (max) | 240V |
Installation CD | Yes |
Response time | 4 ms |
Operating humidity range | 0 - 95% |
Input operating voltage (min) | 151 V |
Power socket | C20 coupler |
Operating altitude | 0 - 3000 m |
Charging time | 5 hours |
USB 2.0 port quantity | 1 |
Depth | 683 mm |
Form factor | Rack mounting |
Packaging width | 600 mm |
Ethernet LAN ports quantity (RJ-45) | 1 |
Operating temperature range | 0 - 40°C |
Battery technology | Lead Acid (VRLA) |
Waveform | Sinusoidal |
Rack capacity | 2U |
Harmonized System (HS) Code | 85078000 |
Quantity of AC outlets | 9 AC outlet(s). |
Temperature range | -15 - 45 °C |
Energy overload evaluation | 375 J |
Acoustic emission | 55dB |
Audible alarms | Yes |
Product color | Black |
Output power | 1980W |
LED indicators | Yes |
Input frequency | 50/60 Hz |
Length | 480 mm |
Output operating voltage (min) | 220V |
Packaging weight | 49.6kg |
Height | 86 mm |
Non-operating altitude | 0 - 15000 m |
Packaging height | 254 mm |